When an Intermatic T100-series time switch stops advancing, the clock motor is usually the part that failed, not the whole timer. This is the 125 VAC, 60 Hz replacement motor for the Intermatic T101, T103 and T105 time switches (current part number WG1570-10D). Its fixed tab connectors slip over the timer's connection posts, so a service electrician can swap the motor and keep the existing enclosure and wiring.
Why service electricians pick it
- Repairs a T101, T103 or T105 without replacing the whole time switch.
- Fixed tab connectors slip onto the timer's posts for quick installation.
- High-torque 60 Hz synchronous motor keeps the dial on time.
- UL and CSA listed replacement part.
Specifications
| Spec |
Detail |
| Brand |
Intermatic |
| Model |
WG1570-10 (current: WG1570-10D) |
| Type |
Replacement timer motor |
| Voltage |
125 VAC, 60 Hz |
| Fits |
T101, T103, T105 time switches |
| Connection |
Fixed tab connectors |
| Listings |
UL, CSA |
Pro tip from the counter
The motor voltage must match the time switch's motor rating, not the load: the T101, T103 and T105 use this 125 V motor, while Intermatic's 208-277 V T100-series models take a different motor. After the swap, reset the time of day on the dial, since the dial stood still for as long as the old motor was dead.
Best for: repairing T101, T103 and T105 time switches, parking lot and sign lighting timers, pool pump timers, facility maintenance spares
Ships across Canada from Vaughan, ON. Maintenance departments keeping spares can ask for a quote or call (905) 553-7171.