{"product_id":"ouellet-oac02000bl-commercial-wall-fan-heater-2000w-240-208v-white","title":"Ouellet OAC02000BL Commercial Wall Fan Heater 2000W 240\/208V, White","description":"\u003cp\u003eThe \u003cstrong\u003eOuellet OAC02000BL\u003c\/strong\u003e is a commercial wall fan heater rated 2000 \/ 1500 W at 240 \/ 208 V, finished in white. On the job it is the commercial workhorse - a heavy-gauge fan-forced wall heater for shops, warehouses, stairwells, garages and vestibules where a residential unit would not survive the duty cycle.\u003c\/p\u003e\n\u003ch3\u003eTL;DR\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e 2000 \/ 1500 W at 240 \/ 208 V (6,830 \/ 5,120 BTU\/h)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDraw:\u003c\/strong\u003e about 8.3 A - size the circuit at 125% per CEC 8-104\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinish:\u003c\/strong\u003e White\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl:\u003c\/strong\u003e not included - needs a line-voltage thermostat\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailability:\u003c\/strong\u003e in stock in Vaughan, ON. Ships Canada-wide, counter pickup available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQuick Specs\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOAC02000BL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCommercial Wall Fan Heater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 \/ 1500 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 \/ 208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6,830 \/ 5,120 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFinish\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e410 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOuellet Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShops, garages, warehouses and mechanical rooms\u003c\/li\u003e\n\u003cli\u003eCommercial entry vestibules and stairwells\u003c\/li\u003e\n\u003cli\u003eLoading docks and back-of-house spaces on 208 V or 240 V services\u003c\/li\u003e\n\u003cli\u003eBuildings replacing gas unit heaters as the gas line comes out\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Contractors Choose It\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2000 W to 4000 W from a single wall-mounted unit - no suspended mounting required\u003c\/li\u003e\n\u003cli\u003eHeavy-gauge enclosure and commercial-duty motor built for continuous cycling\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermostat models remove a separate control run\u003c\/li\u003e\n\u003cli\u003eOffered across 208 V, 240 V and 347 V so it lands on whatever service the building has\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChoose the Right Model\u003c\/h3\u003e\n\u003cp\u003eOuellet builds this series across the wattages and supply voltages Canadian buildings actually run. Match the part number to the service you have:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/commercial-wall-fan-heater-2000w-208v-1ph-white-stat-1p\"\u003eOAC02008BL-T\u003c\/a\u003e - 208 V\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/oac03000bl-t\"\u003eOAC03000BL-T\u003c\/a\u003e - 3000 \/ 2250 W\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/oac04000am-t-wall-fan-heater-230-v\"\u003eOAC04000AM-T\u003c\/a\u003e - 4000 \/ 3000 W, almond\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ouellet-oac04000bl-commercial-wall-fan-heater-4000w-230v-white\"\u003eOAC04000BL\u003c\/a\u003e - 4000 \/ 3000 W\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/products\/ouellet-oac04008bl-t-commercial-wall-fan-heater-4000w-208v-white\"\u003eOAC04008BL-T\u003c\/a\u003e - 4000 W, 208 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eCEC Section 62 governs the install; CEC 8-104 sets conductors and breaker at 125% of nameplate. Commercial units on 208 V or 347 V feeders must land on the correct phase configuration - confirm the building supply before ordering. A disconnecting means is required per CEC 62-108.\u003c\/p\u003e\n\u003ch3\u003eCommon Mistakes to Avoid\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOrdering 240 V for a 208 V building service and losing 25% of the rated output\u003c\/li\u003e\n\u003cli\u003eSkipping the disconnecting means required by CEC 62-108\u003c\/li\u003e\n\u003cli\u003eMounting too low - commercial fan heaters are designed to throw from height\u003c\/li\u003e\n\u003cli\u003eUndersizing the branch circuit; these are continuous loads sized at 125%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Ouellet OAC02000BL CSA certified for use in Canada?\u003c\/strong\u003e\u003cbr\u003eOuellet is a Quebec manufacturer and its heating products are built to Canadian standards and certified for the Canadian market. Confirm the certification mark and the ratings on the unit's own nameplate against your local amendments before you energize it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhere does Maple Electric Supply ship this from?\u003c\/strong\u003e\u003cbr\u003eFrom our own stock in Vaughan, Ontario. That means no cross-border wait, no duty and no surprise brokerage on a heater you need before the cold hits. Counter pickup is available, and we ship across Canada.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 2000 \/ 1500 W rating on the OAC02000BL actually mean?\u003c\/strong\u003e\u003cbr\u003eThis unit is dual-rated. On a 240 V supply it delivers 2000 W. Put the same unit on a 208 V supply and output drops to about 1500 W - roughly 75%, because output falls with the square of the voltage. Order on the voltage the building actually has, not the one on the drawing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat size breaker and wire does the OAC02000BL need?\u003c\/strong\u003e\u003cbr\u003eThe unit draws about 8.3 A at 240 V. Fixed electric heat is a continuous load, so CEC 8-104 sizes the conductor and the breaker at 125% of that - about 10.4 A. Your electrician sizes the final circuit against everything else on it; a 15 A 240 V circuit tops out at 2880 W of total connected heat.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much heat is 2000 W in a real room?\u003c\/strong\u003e\u003cbr\u003e6,830 \/ 5,120 BTU\/h. As a working rule of thumb for an insulated Ontario room, budget roughly 10 W per square foot for a well-insulated space and closer to 15 W per square foot for a basement, a room over a garage or anything with a lot of glass. Send us the dimensions and we will size it properly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the OAC02000BL include a thermostat?\u003c\/strong\u003e\u003cbr\u003eNo - this is the base unit and it needs a control. You can either run a line-voltage wall thermostat, or order the equivalent part number with a factory-installed thermostat built in. We stock both, plus the Ouellet stats that suit them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a disconnect for this commercial heater?\u003c\/strong\u003e\u003cbr\u003eYes. CEC 62-108 requires a disconnecting means for fixed electric heating equipment - within sight of the unit, or lockable in the open position. On a suspended or ceiling-mounted unit that is not optional and inspectors look for it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this replace a gas unit heater?\u003c\/strong\u003e\u003cbr\u003eOften, yes - and it removes the venting, the gas piping, the combustion air and the annual gas inspection along with it. The question is whether the electrical service has capacity for the load. Send us the existing gas heater's BTU rating and your available service and we will tell you what it takes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I get a price on a full job's worth?\u003c\/strong\u003e\u003cbr\u003eYes. Multi-unit and contractor pricing is available on Ouellet heating - send the schedule or the count and we will quote it. Most heating orders over a handful of units are priced by our counter team rather than at list.\u003c\/p\u003e\n\u003cp\u003eKept on the shelf in Canada by Maple Electric Supply. Free shipping over $150 in Ontario and Quebec, counter pickup in Vaughan, and contractor pricing on multi-unit orders.\u003c\/p\u003e","brand":"Ouellet","offers":[{"title":"Default Title","offer_id":44922605142147,"sku":"OAC02000BL","price":883.2,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1804\/8655\/files\/OAC_b0edd461-3eea-4d2c-bdb2-c43cb3182870.jpg?v=1730722491","url":"https:\/\/mapleelectricsupply.ca\/products\/ouellet-oac02000bl-commercial-wall-fan-heater-2000w-240-208v-white","provider":"Maple Electric Supply ","version":"1.0","type":"link"}